3981 Cleveland Ave
Columbus, OH 43224
614-475-1800

Local Reviews
for grove city, oh

Rated 5.0 out of 5 stars based on 5 customer reviews

Great service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Terrific

Josh did my annual check up on furnace and also installed a humidifier. Josh thoroughly explained humidifier operation and it’s effectiveness. Excellent service.


Response from Sears Heating & Cooling:

We are so grateful for your 5-star review. Thanks for sharing your rating with us and the community.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great technician

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and price !

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great guy

Enjoyed talking Hvac with our sears rep!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for grove city, oh

Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2017 terrain air conditioning system found 40/5 voltage absorption system reading 36.5/5. Found 109 in Rush amps. Left new 2025 one filter. Advise customer to expect issues with voltage absorption system in upcoming years though part is not outside manufacture specifications at this time. Offered to quote for part, customer asked for ballpark price ballpark 350–400 customer wants to wait until next year to see if it is outside manufacture specifications


Josh S.

Josh S. Job Checkin

2019 hp Goodman Compressor is bad No filter dryer

2019 hp Goodman 
Compressor is bad 
No filter dryer

Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on Bryant AC system. Found 45/5 voltage absorption system reading 45/5. Replaced 20251 filter. No issues at this time.


Robby D.

Robby D. Job Checkin

Responded to no heat situation found no active faults. Pulled last 10 faults. Last fault stored was  3/26 for humidity  sensor.  Proceeding fault is limit fault on 3/24 system currently satisfied at 69 degree customer Still has 16244 filter in 413 filter rack. Filter is dirty, restricted  due to improper size as well allowing air to bypass  advised proper 413 filter needs to be installed to prevent airflow issues registers open dirty return grilles advised may benefit from duct cleaning as Customer stated we replaced 16254 filter at last visit cannot confirm or deny. Offered to replace with proper filter customer is to price check and order online Replaced with customer supplied 16254 filter today customer will replace again with proper filter when he gets it. Furnace running upon departure 73 RA 113 SA. 40 degree delta t. 0 ppm ambient co


Wally T.

Wally T. Job Checkin

Annual maintenance check on Bryant air conditioner


Robby D.

Robby D. Job Checkin

Upon arrival pulled last 10 system events stat showing limit fault and g input being sent together. Fault happened twice yesterday, furnace running properly satisfied at stat with no active codes. Found customer had most supply resisters in first floor closed/ blocked off. Advised to open registers for maximum airflow. Customer using 16254 filter in place of 413. Advised 4 inch filter will restrict airflow 1”+ around perimeter of filter. Best to use 413 filter for max airflow. Found 4 dampers closed. Opened all dampers. Furnace is running upon departure with no issues.


Robby D.

Robby D. Job Checkin

Customer had concern with leaking humidifier. Stated that black buildup caused blockage in clear tubing. Customer removed and cleaned with pipe cleaners. Asked if issue is normal. Advised slight buildup and discoloration is normal but not a full clog. Inquired about hard water. Customer stated water filtration system had issues, advised those issues could cause worse buildup then normal pad quite used replaced in august but looks as if hadn’t been replaced in multiple years. Advised filter issues seems to be cause. Customer has issues with dryer vent. Dryer is in pamper room with vent inside wall. Wanted hard pipe to wall inlet. Advised dryer would need to be moved out to hard pipe. Roughly 4-5 inches pulled dryer out as rough ballpark. Customer was not satisfied and looking into a more rigid flex pipe to avoid buildup in pinched pipe., customer has insufficient return air upstairs. Interested in mini split installed in main hallway foyer to accommodate in heating and cooling seasons.


Josh S.

Josh S. Job Checkin

Found bad heat exchanger 2006 single stage 90% Bryant New furnace is going in on Monday at 8am

Found bad heat exchanger 2006 single stage 90% Bryant New furnace is going in on Monday at 8am

Wally T.

Wally T. Job Checkin

Annual maintenance check on a Bryant heat pump


Jamie S.

Jamie S. Job Checkin

Provided a complimentary estimate to replace an electric furnace and install a new heat pump.

Provided a complimentary estimate to replace an electric furnace and install a new heat pump.

Josh S.

Josh S. Job Checkin

Sequencer is bad on two He will replaced like he did last time Wiring on 3 wired were loose and broken Hp is working good Filter is replaced 18-20-1 Added tab

Sequencer is bad on two 
He will replaced like he did last time 
Wiring on 3 wired were loose and broken 
Hp is working good 
Filter is replaced 18-20-1
Added tab

Josh S.

Josh S. Job Checkin

2 stage Bryant 80% attic unit Check Stat. Does unit come on?: Yes Does the customer have any IAQ products?: No Did you change the filter?: left behind Added tab

2 stage Bryant 80% attic unit 
Check Stat. Does unit come on?: Yes
Does the customer have any IAQ products?: No
Did you change the filter?: left behind 
Added tab

Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 16 rheem furnace. Found 10%o2. 14 ppm co in flu. 0 ppm co in supply. Left new 16251. Customer opted for humidifier coverage. Upon startup humidifier failed to cycle. Found very slow drip from water supply. Saddle valve opened up with little persuasion. Humidifier properly cycled on and off through humidistat, 55 degree deltat.


Josh S.

Josh S. Job Checkin

Rheem 90% 2014 Filter 413-410 Flame sensing system is clean Trapping systems are good Electrical is secure Wp 10 and is all set up for winter Comin flue is 19 ppm good I changed her controller back to the existing due to better ability to use and inspection is over She will save t4 Filter is clean

Rheem 90% 2014 
Filter 413-410
Flame sensing system is clean 
Trapping systems are good 
Electrical is secure 
Wp 10 and is all set up for winter 
Comin flue is 19 ppm good 
I changed her controller back to the existing due to better ability to use and inspection is over   She will save t4 
Filter is clean

Josh S.

Josh S. Job Checkin

Filter 16-25-1 Co in flue 18ppm Electrical is secure Flushed trap and hoses

Filter 16-25-1 
Co in flue 18ppm 
Electrical is secure 
Flushed trap and hoses